Modbus TCP Debug Tool

A free, open-source diagnostic tool for testing Modbus TCP connections to solar inverters and energy meters. Download a single binary, run it, and get a clear answer about whether your device's Modbus TCP is working — no installation required.

Built by Sourceful Energy — the makers of the Zap, a gateway for local energy coordination. This tool speaks the same Modbus TCP protocol as the Zap, making it the perfect companion for verifying your inverter setup before or during deployment.

This is a read-only tool — it never writes to your inverter registers. Safe to use at any time.

Download

Grab the latest binary for your platform from Releases.

Platform File Notes
macOS (Apple Silicon) modbus-debug-darwin-arm64 M1/M2/M3/M4 Macs
macOS (Intel) modbus-debug-darwin-amd64 Older Macs
Windows modbus-debug-windows-amd64.exe 64-bit Windows
Linux modbus-debug-linux-amd64 64-bit x86
Linux (ARM) modbus-debug-linux-arm64 Raspberry Pi 4+, etc.

How to Run

macOS

macOS blocks unsigned binaries by default. Open Terminal and run:

# Remove the quarantine flag (one-time)
xattr -d com.apple.quarantine modbus-debug-darwin-arm64

# Make it executable and run
chmod +x modbus-debug-darwin-arm64
./modbus-debug-darwin-arm64

Alternatively: right-click the file in Finder → Open → click "Open" in the dialog.

Windows

Double-click modbus-debug-windows-amd64.exe or run it from Command Prompt.

Windows Firewall will ask to allow network access — click "Allow". The tool needs to reach devices on your local network. It only listens on 127.0.0.1 (your machine only), so it's not accessible from other computers.

Linux

chmod +x modbus-debug-linux-amd64
./modbus-debug-linux-amd64

No root required — the tool connects to port 502, it doesn't listen on it.

Using the Tool

When you run the binary, your browser automatically opens to http://127.0.0.1:8765. You'll see a guided wizard with two modes:

Guided Wizard (recommended)

Step-by-step diagnostic — perfect for troubleshooting:

  1. Network Scan — Scans your local network for devices with Modbus TCP ports open (502, 1502, 8899, 6607). Pick a discovered device or enter an IP manually.

  2. TCP Test — Verifies that a TCP connection to the device succeeds and measures response time.

  3. Inverter Detection — Reads identification registers across 20 known inverter profiles to determine the device brand and model. Tries slave IDs 1, 0, and 247 automatically.

  4. Register Read — Reads all registers for the detected profile (PV production, battery state, grid power, meter values) and decodes them with the correct data types and scale factors.

  5. Diagnostic Report — Generates a text report you can copy/paste into Discord, email, or a support ticket:

=== Sourceful Modbus Diagnostic Report ===
Date: 2026-03-07 15:30
Tool: v0.1.0

[NETWORK]
  Target: 192.168.1.50:502  |  TCP: OK (12ms)  |  Slave ID: 1

[DETECTION]
  Brand: Sungrow SH Hybrid  |  Serial: SG12345678

[REGISTERS] 17/17 OK
  PV Power:       3250 W      [OK]
  Battery SoC:    67.3 %      [OK]
  Grid Frequency: 50.02 Hz    [OK]
  ...
=== End Report ===

Manual Mode (power users)

Read any Modbus register directly:

  • Connect to any IP:port with any slave ID
  • Read holding or input registers at any address
  • Choose register count and data type (U16, I16, U32, I32, F32, STR)
  • See raw values and decoded results
  • Useful for unsupported brands or debugging specific registers

Supported Devices

20 inverter and meter profiles with full register maps:

Brand Model Detection Register Default Port
Sungrow SH Hybrid 4989 (holding) 502
Huawei SUN2000 30015 (holding) 6607
Solis Hybrid 33004 (input) 8899
Fronius GEN24 Plus 40052 (holding, SunSpec) 502
Deye Hybrid 3 (holding) 8899
SolarEdge StorEdge 40052 (holding, SunSpec) 502
SMA Sunny Tripower 30057 (holding) 502
Pixii PowerShaper 2 40052 (holding, SunSpec) 502
Eastron SDM630 (meter) 64512 (input) 502
Fronius Smart Meter TS 65A-3 40053 (holding, SunSpec) 502
Ferroamp EnergyHub 2000 (input) 502
GoodWe ET/EH/BH/BT Hybrid 35003 (holding) 502
Growatt Hybrid 23 (holding) 502
SolaX X1/X3 768 (holding) 502
SofarSolar HYD G3 1093 (holding) 502
Victron Energy (GX) 800 (input) 502
FoxESS H3 30000 (holding) 502
Alpha ESS SMILE 1610 (holding) 502
E3DC S10/E 40000 (holding) 502
SAJ H2 36611 (input) 502

Scanned Ports

Port Devices
502 Standard Modbus TCP (most inverters)
1502 Kostal, some alternative setups
8899 Deye, Solis, Sofar Wi-Fi dongles
6607 Huawei SmartDongle

Troubleshooting

No devices found during network scan

  • Make sure your computer is on the same network as the inverter
  • Verify Modbus TCP is enabled in your inverter's settings menu
  • Some Wi-Fi dongles take 30-60 seconds to boot — wait and retry

"Connection refused"

  • The inverter's Modbus TCP service may not be enabled
  • Some inverters allow only one TCP connection at a time — disconnect the Zap or any other Modbus client first, then retry

"Connection timed out"

  • Double-check the IP address (look in your router's DHCP client list)
  • A firewall may be blocking connections to port 502
  • Wi-Fi dongles (Deye, Solis) can be slow — the tool automatically adjusts timeouts for slow connections

Can't detect inverter type

  • Your inverter may use a non-standard slave ID — the wizard tries 1, 0, and 247 automatically
  • Use Manual Mode to try other slave IDs or read specific registers
  • If your brand isn't listed, the tool still generates a report with what it found — share it with support

Register values look wrong

  • Check that the correct profile is selected — a wrong profile will decode registers incorrectly
  • Some inverters require specific slave IDs (e.g., Victron uses 100, Alpha ESS uses 85)
  • Values of 0 may mean the inverter is in standby/night mode

CLI Options

Usage: modbus-debug [options]

Options:
  -port int        HTTP server port (default 8765)
  -no-browser      Don't auto-open browser on start

Example: run on a different port without opening the browser:

./modbus-debug -port 9090 -no-browser

Building from Source

Requires Go 1.22+.

# Clone the repo
git clone https://github.com/srcfl/modbus-debug.git
cd modbus-debug

# Build for your current platform
make build

# Cross-compile all platforms
make build-all

# Run tests
make test

# Run directly
make run

Output binaries are in the bin/ directory. All builds are statically linked (CGO_ENABLED=0) with no external dependencies (~8 MB).

Contributing

Found a bug or want to add support for a new inverter brand? Open an issue or submit a PR.

To add a new device profile, create a file in internal/modbus/devices/ following the pattern of existing profiles (e.g., sungrow.go). Each profile defines register addresses, data types, endianness, and scale factors.

License

MIT — see LICENSE

About

Modbus TCP diagnostic tool for solar inverters — single binary, browser-based wizard